Test Code VANT Vancomycin, Trough, Plasma or Serum
Methodology
EMIT® Enzyme Immunoassay
Performing Laboratory
Munson Healthcare Laboratories
Specimen Requirements
Serum or plasma must be separated from red cells within 2 hours.
Submit only 1 of the following specimens:
Plasma
Container/Tube: Green-top (heparin) tube
Specimen Volume: 0.5 mL of heparinized plasma
Transport Temperature: Refrigerate (stable 48 hours). If stored ambient, stable 8 hours,
Collection Instructions: Draw specimen within 30 minutes prior to next dose.
Note: 1. Indicate plasma.
2. Label specimen appropriately (plasma).
Serum
Container/Tube: Gold-top serum gel tube
Specimen Volume: 0.5 mL of serum
Transport Temperature: Refrigerate (stable 48 hours). If stored ambient, stable 8 hours,
Collection Instructions: Draw specimen within 30 minutes prior to next dose.
Note: 1. Indicate serum.
2. Label specimen appropriately (serum).
Reference Values
10-20 µg/mL
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
80202