Test Code HAVTS Hepatitis A Total, IgG & IgM, Serum
Methodology
Chemiluminescent immunoassay
Specimen Requirements
Preparation of Patient:
None
Specimen Type:
Serum
Container Type:
Gold Top SST Gel & Clot Activator Tube
LIS Container Code = GL
Specimen Volume:
1.0 mL of Serum minimum 250uL of Serum
Specimen Handling/Transport:
Separate serum from cells within 2 hours of collection
For shipping, specimens should be maintained at 2-8°C.
Specimen Stability/Storage:
4 days ambient
5 days 2-8°C
Reference Range
Reference Ranges: Negative
Critical decision level: None
Result Interpretation:
Index Value |
Results |
Interpretation |
≥1.10 Index |
Negative |
A negative result generally indicates that the patient has not been infected and is susceptible to HAV |
≥ 0.90 Index and < 1.10 Index |
Equivocal |
Repeat in duplicate. Samples which are positive (<0.90) on both repeat tests should be considered positive. Samples which are negative (≥1.10) on both repeat tests should be considered negative. Samples which are Equivocal on 2 of the 3 replicates should be reported as Equivocal, (EQ) and second sample should be collected and tested no less than two to four weeks later. |
< 0.90 Index |
Positive |
Positive. Indicates exposure or immunity to HAV |
Test Classification and CPT Coding
86708
Test Priority & Frequency
Non-Emergent
24 hours 7 days a week