Test Code DIG Digoxin, Plasma or Serum
Methodology
EMIT® Enzyme Immunoassay
Performing Laboratory
Munson Healthcare Laboratories
Specimen Requirements
Specimen must arrive within 24 hours of draw.
Submit only 1 of the following specimens:
Plasma
Container/Tube: Green-top (heparin) gel tube
Specimen Volume: 0.5 mL of heparinized plasma
Transport Temperature: Refrigerate
Collection Instructions: Specimens for digoxin should be drawn at least 6 hours after the last oral dose of digoxin has been given. Forward promptly.
Note: 1. Medicare frequency limitations exist for this test in addition to diagnosis requirements. Click on link for list of medically necessary diagnoses: http://www.munsonhealthcare.org/medical-necessity. See Advance Beneficiary Notice of Noncoverage (ABN) form in Special Instructions.
2. Indicate plasma.
3. Label specimen appropriately (plasma).
Serum
Container/Tube: Gold-top serum gel tube
Specimen Volume: 0.5 mL of serum
Transport Temperature: Refrigerate
Collection Instructions: Specimens for digoxin should be drawn at least 6 hours after the last oral dose of digoxin has been given. Forward promptly.
Note: 1. Medicare frequency limitations exist for this test in addition to diagnosis requirements. Click on link for list of medically necessary diagnoses: http://www.munsonhealthcare.org/medical-necessity. See Advance Beneficiary Notice of Noncoverage (ABN) form in Special Instructions.
2. Indicate serum.
3. Label specimen appropriately (serum).
Reference Values
0.8-2.0 ng/mL
Critical value (automatic call-back): ≥ 2.0 ng/mL
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
80162