Test Code BUNDIAL Urea Nitrogen Dialysate
EHR Test Codes
| Test Code | Test Name | |
| Atlas | BUNDIAL | Urea Nitrogen, Dialysate |
| Cerner | Urea Nitrogen Dialysate |
Specimen Requirements
Preparation of Patient:
None
Container Type:
Sterile Container
Specimen Type:
Body Fluid - Peritoneal Dialysis Fluid
Specimen Volume:
3 mL of body fluid minimum 1.0 mL
Specimen Handling/Transport:
Fluid should be removed from the cells within 1 hour of collection.
Transport ambient room temperature.
Specimen Stability/Storage:
5 days refrigerated 2-8°C
Specimen Rejection:
pH outside 7-8 range
Performing Laboratory
Munson Medical Center Laboratories
Chemistry Department
Priority, Frequency, & Turnaround
Priority:
STAT, ASAP, Non-Emergent
Frequency:
24 hours 7 days a week
Turnaround:
0 - 1 days
STAT 60 minute from receipt in lab
Methodology
Urease GLDH
Reporting
Reference Range:
BF pH 7.5 - 8.5
Interpretive Data:
The reference interval and other method performance specifications have not been established for this body fluid. The test result must be integrated into the clinical context for interpretation. This is an FDA modified test.
Critical Decision:
None
Clinical Significance
Dialysate BUN is used to calculate adequacy of a dialysate event.
CPT Code(s)
84520