Test Code APH pH, Arterial (Includes pCO2 Arterial), Blood
Methodology
Ion-Selective Electrode (ISE)
Performing Laboratory
Munson Healthcare Laboratories
Specimen Requirements
Specimen must arrive within 10 minutes of draw.
Container/Tube: Blood gas capillary tube or heparinized syringe-Specimen exposed to air is not acceptable.
Specimen Volume: 0.1 mL of whole blood from blood gas capillary tube or 0.5 mL of whole blood from heparinized syringe
Transport Temperature: Ambient
Collection Instructions: Forward immediately. Specimen must be analyzed within 30 minutes of draw.
Note: Do not centrifuge.
Reference Values
pH: 7.34-7.44 pH units
Critical values (automatic call-back):
2 months - ≥90 years: </= 7.20 pH units or >/= 7.60 pH units
<2 months: <7.20 pH units or >7.50 pH units
pCO2: 32-44 mm/Hg
Critical values (automatic call-back): </= 20 mm/Hg or >/= 70 mm/Hg
Day(s) Test Set Up
Monday through Sunday
Test Classification and CPT Coding
82803