Test Code ALBBF Albumin Level Body Fluid
EHR Test Codes
| Test Code | Test Name | |
| Atlas | ||
| Cerner | Albumin Level Body Fluid |
Specimen Requirements
Preparation of Patient:
None
Container Type:
Sterile Container
Specimen Type:
Body Fluid - Peritoneal Fluid, Peritoneal Dial, Pleural, or Pericardial
Specimen Volume:
3 mL of body fluid
Specimen Handling/Transport:
Fluid should be removed from the cells within 1 hour of collection.
Transport refrigerated 2 - 8oC.
Specimen Stability/Storage:
5 days refrigerated 2-8°C
Specimen Rejection:
pH outside 7-8 range
Performing Laboratory
Munson Medical Center Laboratories
Chemistry Department
Priority, Frequency, & Turnaround
Priority:
STAT, ASAP, Non-Emergent
Frequency:
24 hours 7 days a week
Turnaround:
0 - 1 days
STAT 60 minute from receipt in lab
Methodology
Photometric - Bromocresol Green (BCG)
Reporting
Reference Range:
7.5 - 8.5 g/dL
Interpretive Data:
The reference interval and other method performance specifications have not been established for this body fluid. The test result must be integrated into the clinical context for interpretation. This is an FDA modified test.
Critical Decision:
None
Clinical Significance
A serum to effusion albumin gradient (serum albumin minus fluid Albumin) can be helpful in determination of a transudate or exudate. A value less than 1.1 g/dL is seen in exudates.
CPT Code(s)
82042